Hot Concern
- 4-72 glass reinforced plastics is
- Glass reinforced plastics twines c
- Glass reinforced plastics twines c
- Conduit of inorganic glass reinfor
- Circle of glass reinforced plastic
- Tower of refrigeration of glass re
- Glass reinforced plastics purifies
- The axis sheds T35-11 glass reinfo
- Canister of soft water of glass re
- Supply axis of T35-11 glass reinfo
Random Recommendation
- 4-72 glass reinforced plastics is
- Glass reinforced plastics twines c
- Glass reinforced plastics twines c
- Glass reinforced plastics purifies
- The axis sheds T35-11 glass reinfo
- Tower of refrigeration of glass re
- Canister of soft water of glass re
- Circle of glass reinforced plastic
- Conduit of inorganic glass reinfor
- Supply axis of T35-11 glass reinfo
Position:home>The supply of information>
Glass reinforced plastics purifies a tower
From; Author:Stand originally
When 2, fan is installed, should take strict precautions against sundry drop fan inside. After purifying a tower to install silk, must keep clear of before test-drive the contamination inside the tower.
3, because general glass reinforced plastics is combustible, in installation and maintenance process, forbidden use bright internal heat.
Chroma of solution of the NaOH inside box of fluid of 4, lay aside should maintain inside 2-6% limits, when NaOH chroma under 2% when, must add note NaOH solution. The waste liquid in box of lay aside fluid should use a circumstance to undertake changing according to solid younger sister.
5, install like fan indoors, the electric machinery of fan should take the step that prevent rain.
6, purify a tower to must have government of responsibility of person specially assigned for a task, it is normal to often check fan to run, fluid whether political fluid switch of ball of the float in box is normal, whether is NaOH solution chroma waited a moment in formulary limits, if discover a problem, answer to be solved in time.
7, to ensure box of lay aside fluid is medium fluid, fluid is caused when preventing switch fan litre fall, must be after open fan, a powerful person of water supply of open float ball, before shutting fan, close valve of float ball water supply first. Fluid high static state should be controlled it is advisable to be controlled in 650mm leaving the ground.
8, purify tower metal bracket to undertake anticorrosive processing every year 2 times at least.
Unit name: Limited company of glass reinforced plastics of strong county of Heibei province jujube [standard member]
Contact: Yu Fei
Connect a telephone call: 0318-8386990
Mobile phone: 13932829912/13171717671
Fax: 0318-7056406